Stimulus Scanfield
A stimulus scanfield is defined by the following properties
Definition of a StimulusField
hSf = scanimage.mroi.scanfield.fields.StimulusField(); % create a stimulus Scanfield
hSf.centerXY = [0.5,0.5]; % define the [x,y] center of the stimulus pattern (in reference space)
hSf.sizeXY = [0.5,0.5]; % define the [x,y] size stimulus pattern (in reference space)
hSf.rotationDegrees = 0; % define the rotation of the stimulus pattern (in reference space)
hSf.stimfcnhdl = @scanimage.mroi.stimulusfunctions.logspiral; % define the function handle used to generate the stimulus pattern
hSf.stimparams = {'revolutions',10}; % additional parameters passed to the function generating the stimulus pattern
hSf.duration = 0.01; % define the duration of the stimulus in seconds
hSf.repetitions = 1; % define the number of repeats of the stimulus
hSf.powers = [1]; % define the power for each beam delivered during the stimulus in percent
hRoi = scanimage.mroi.Roi(); % create an empty Roi
hRoi.add(0,hSf); % add the stimulus Scanfield to the Roi
Stimulus Sequence
To create a stimulus sequence, multiple stimulus rois can be added to a RoiGroup.
Setup of a Stimulation Sequence
%% create template Stimulation Roi hSf = scanimage.mroi.scanfield.fields.StimulusField(); % create a stimulus Scanfield hRoi = scanimage.mroi.Roi(); % create an empty Roi hRoi.add(0,hSf); % add the scanfield to the Roi; Currently ScanImage only supports stimulation at z=0 %% create multiple stimulus Rois from template hRoi1 = hRoi.copy(); % create deep copy of template Roi hRoi1.scanfields(1).centerXY = [0.25,0.5]; % change the position of the stimulus hRoi2 = hRoi.copy(); % create deep copy of template Roi hRoi2.scanfields(1).centerXY = [0.5,0.5]; % change the position of the stimulus hRoi3 = hRoi.copy(); % create deep copy of template Roi hRoi3.scanfields(1).centerXY = [0.75,0.5]; % change the position of the stimulus stimRois = [hRoi1 hRoi2 hRoi3]; % collect the position of the stimulus Rois in array %% create pause Roi hSfPause = scanimage.mroi.scanfield.fields.StimulusField(); % create a stimulus Scanfield hSfPause.stimfcnhdl = @scanimage.mroi.stimulusfunctions.pause; % the pause stimulus function allow for a smooth transition between stimuli hSfPause.duration = 0.01; % allow enough time for the mirrors to transition in between stimuli hRoiPause = scanimage.mroi.Roi(); % create an empty Roi hRoiPause.add(0,hSfPause); % add 'pause' stimulus to Roi %% create park Roi hSfPark = scanimage.mroi.scanfield.fields.StimulusField(); % create a stimulus Scanfield hSfPark.stimfcnhdl = @scanimage.mroi.stimulusfunctions.park; % the park stimulus function moves the mirrors to the park position hSfPark.duration = 0.01; % allow enough time for the mirrors to traverse to the park position hRoiPark = scanimage.mroi.Roi(); % create an empty Roi hRoiPark.add(0,hSfPark); % add 'park' stimulus to Roi %% create roiGroup containing sequence of stimuli hRoiGroup = scanimage.mroi.RoiGroup(); % add all stimuli, interleave with pauses for idx = 1:length(stimRois) hRoiGroup.add(hRoiPause); hRoiGroup.add(stimRois(idx)); end hRoiGroup.add(hRoiPark); % transition to park position at end of sequence hSI.hPhotostim.stimRoiGroups(end+1) = hRoiGroup; % add sequence to array of stimRoiGroups