POWER CONTROLS Panel
Overview
The POWER CONTROLS panel pertains to the (optional) control of a voltage-controlled light modulator (typically a Pockels cell), allowing the power level used during image acquisition to be controlled.
Main Panel
Specifies the time to advance beam control to compensate for lag in the response of the light modulation device. | |
Specifies whether or not to blank the light modulation outside the line acquisition period, during frame flyback, and during fastZ flyback frames. | |
Lists all beams configured in the system and some settings for each. The checkbox in the first collumn selects which beam to display detailed settings for below. The rest of the collumns mirror settings detailed in the next section. | |
Enables power box | |
Opens Power Box Settings GUI to modify power box parameters |
Selected Beam Panel
Slider control of the power level. Adjustments take effect immediately. | |
Direct numeric input of the power level. Adjustments take effect immediately. | |
Normally, changes to Power have no immediate effect when not acquiring. For optical measurement & testing purposes, the Direct Mode option can be selected. This causes changes to the Power level to take immediate effect, i.e. Beam has specified power even though no scanning/imaging is being done. This mode can be individually set per beam. If any beam is currently in direct mode the checkbox is highlighted red. | |
The Limit value simply determines the maximum value to allow for the Power level setting, for the specified Beam. This is useful for preventing the value from accidentally being set too high. | |
Drop down menu enables/disables Power vs. Depth adjustment feature and sets the method accordingly for currently selected Beam.
| |
Sets the Power vs. Depth adjustment function for the currently selected Beam to the default exponential function. Power is increased with depth according to: P = P0 * exp^((z-z0)/Lz) | |
Sets the Power vs. Depth adjustment function for the currently selected Beam to the function indicated in the Power/Depth Source field. By Matlab convention this field indicates the name of the .m file containing the function definition to be used. The function name must match exactly the file name. The function should take the arguments startPower, zPowerReference, z in this order. The value and source of these arguments, whether or not they are actively used, as well as the manner in which they are combined is completely up to the user. | |
Sets the Power vs Depth adjustment for the currently selected Beam to follow an interpolation from a specified Look-Up Table given specified z depths. By SI convention the look up table should be an Nx2 matrix with column 1 containing z depths in microns and column 2 the corresponding beam power level for that depth. For z depths not specified in the LUT the default value is 10% power. The LUT can be any file format recognized by Matlab (.mat, .cvs, etc).
| |
Collapses/Expands Power vs. Depth adjustment plot. This is provides a GUI based visual representation of power adjustment with respect to depth. | |
Causes Beam Calibration for currently selected Beam to be remeasured. | |
Displays Matlab figure showing result of most recent Beam Calibration obtained for currently selected Beam. | |
Used to measure voltage offset on Beam Calibration input channel when no laser is present, i.e. offset of light meter and input A/D channel combined. User is prompted to block laser beam for the Beam Calibration offset measurement. All exiting and subsequent calibration curves are adjusted to reflect this input offset. |
KEY POINTS:
- Power is adjusted to specified level immediately while actively imaging, or only when direct mode is on when idle.
- Between acquisitions (i.e. between triggers), the Beam power level output is adjusted to minimum power measured during Beam Calibration – i.e. the Beam is 'OFF'
- The command signal generated by ScanImage for selected Beam will alternate between the specified Power level and the minimum power (during scanner flyback or turnaround)
Attachments:
enpb.png (image/png)
Power.png (image/png)
measureoffsets.png (image/png)
showcurve.png (image/png)
calibrate.png (image/png)
lz.png (image/png)
enablepz.png (image/png)
powerlimit.png (image/png)
direct.png (image/png)
powernumber.png (image/png)
powerslider.png (image/png)
beamlist.png (image/png)
blankflyback.png (image/png)
leadtime.png (image/png)
image2014-6-3 20:1:1.png (image/png)
powercontrolsc02.png (image/png)
powercontrolsc01.png (image/png)
powercontrolsb01.png (image/png)
powercontrolsa06.png (image/png)
powercontrolsa05.png (image/png)
powercontrolsa04.png (image/png)
powercontrolsa03.png (image/png)
powercontrolsa02.png (image/png)
powercontrolsa01.png (image/png)
PowerControlsPulldown.png (image/png)
PowerControls.png (image/png)
image2016-8-2 13:10:16.png (image/png)
image2016-8-2 13:13:53.png (image/png)
image2016-8-2 13:14:26.png (image/png)
image2016-8-2 13:30:15.png (image/png)
image2016-8-2 13:31:24.png (image/png)
image2016-8-2 13:31:58.png (image/png)
image2016-8-2 13:33:6.png (image/png)
image2016-8-2 13:33:40.png (image/png)
image2016-8-2 13:34:10.png (image/png)
image2016-8-2 13:34:36.png (image/png)
image2016-8-2 13:36:36.png (image/png)
image2016-8-2 13:39:19.png (image/png)
image2016-8-2 13:40:17.png (image/png)
image2016-8-2 13:43:9.png (image/png)
image2016-8-2 13:49:29.png (image/png)
image2016-8-2 13:53:19.png (image/png)
image2016-8-2 14:14:21.png (image/png)