General Information
ScanImage 2017b is software for resonant and linear two-photon laser-scanning microscopy.
ScanImage supports numerous microscope platforms and is built on the same flexible acquisition hardware as our public release ScanImage 5.
ScanImage 2017b adds several premium features atop of ScanImage 5.3.1:
- SLM 3D targetting and imaging
- Motion Correction in Z
See ScanImage Licensing for pricing info.
Contact scanimage@vidriotech.com for a quotation or any questions.
Installing ScanImage
To install ScanImage, download and run the installer exe file. The installer will install ScanImage into the program files folder and update the MATLAB path for all releases that you select. If you have existing ScanImage installations, they will be left intact. You can easily revert back to a previous ScanImage installation by changing the MATLAB path to point back to the desired installation.
For more information about initial setup see the getting started page.
Upgrading Information
Unless specifically noted (as indicated by a compatibility note), upgrading from an older release of ScanImage 2017 to a newer build will not break compatibility with Machine Data Files, User files, Configuration files, or TIFF headers. After upgrading, the first time you run ScanImage you will need to browse to the location of your existing machine data file.
Version Notes
SI2017bR0 / SI5.3.1
November Release (10 November 2017)
- SI 5.3.1 (Free version. Features also in Premium)
- SI 2017bR0- Z Motion Correction
- Improved Galvo Waveforms
- Eliminated FastZ Volume Period Adjustment
- Custom Header Properties
- Data Overwrite Warning
- Improved acquisition start time for large volumes
- ROI Display Fixes
 
SI2017aR0 / SI5.3
August Release (30 August 2017)
- SI 2017aR0- 3D SLM targeting and imaging
- 3D pattern generation and alignment
- Simultaneous imaging and holographic targeting
- SLM as FastZ or Linear Scanning device
- Wavefront generation with Zernike modes
- Bessel-mode scanning
- Z-Alignment between stage and focusing device
- SLM LUT calibration
- Triggered SLM photostimulation
 
SI2016bR0 / SI5.2.3
November Release (23 November 2016)
- SI 5.2.3 (Free version. Features also in Premium)- Bugfixes & Performance improvements
 
- SI 2016bR0- SLM support for targeted photostimulation
- Independent Z-control for parallel scanners
- Scanner command waveform optimization
 
SI2016.2 / SI5.2.2
October Release (24 October 2016)
- SI5.2.2 (Free version. Features also in Premium)- Display mode for current slice in stack
- Custom power depth adjustment profiles
- LinScan file logging and averaging updates
- Support for NI-DAQmx 16.0
 
- SI2016.2 (Premium version)- Optimization and caching of waveform AO's
 
SI2016 / SI5.2
June Release (15 June 2016)
- SI2016 (Premium version)- Support for arbitrary line scanning
- Motion correction for photostimulation
- Online analysis (Roi integration)
- Motor alignment
- Full affine alignment between scanners
 
- SI5.2 (Free version)- Live histogram
- FastZ-actuator tuning
- Configuration GUI for microscope configuration
 
SI2015
March Release (10 March 2016)
- Support for NI-DAQmx 15.5
- Support for logging when imaging multiple ROIs in LinScan
- Several bugfixes and performance improvements in LinScan
- Fixes for openTif
January Release (22 January 2016)
- Compatibility Note for Thorlabs BScope 2 users- The MDF entries for the BScope2 component changed. The following link has instructions to modify your configuration for the new version:
 ScanImage January 2016 Release Thorlabs BScope 2 Compatibility Information
 
- The MDF entries for the BScope2 component changed. The following link has instructions to modify your configuration for the new version:
- Support for Thorlabs MCM3000, USB PMT2100, USB BCM
- Support for higher sampling rates on certain DAQs in LinScan
- Fix powerbox with P-Z adjustment
- Improve performance of opentif
- Improved automatic scan phase adjustment for ResScan
- Automatic scan phase adjustment for LinScan
- New NI VISA interface
- Fix several bugs in LinScan
November Release (18 November 2015)
- Powerbox 
- Cycle mode
- Striped acquisition in LinScan (Galvo-Galvo scanning)
- Fixes to LinScan (Galvo-Galvo scanning) when using a PCI-6110 
- Fixes to LinScan (Galvo-Galvo scanning) when performing a Z-stack acquisition
- Performance enhancement for openTiff
August Release (11 August 2015)
- Performance enhancements to acquisition starting and photostimulation starting 
- Performance enhancements to loading of usr and cfg files 
- Option to keep resonant scanner on when no acquisition is active 
- Improved mapping of ROIs from cell picker interface 
- Automatic sensor calibration and max/min position limits for purse analog controller 
- Support for mulitple linear scan paths 
- Support for photon counting modules 
- Improved linear scanning waveform with settling within fill fraction 
- Support for DAQmx 15.0.x 
- Remove TIFF header and footer size limitations 
- Fix centered z stack functionality with fastZ 
- Fix errors in slow stacks with some motors 
- Fix panning channel display in Matlab 2014b and newer 
- Fix scroll wheel functionality in Matlab 2014b and newer 
- Fix reference leaks with ROI group, ROI, and scanfield objects 
- Fix issue where footer is only attached to last TIFF in acquisition 
- Fix loading and storing of photostim monitor calibration 
- Compatibility Note: A new section for photostim will be created in the MDF. Analog input channels for
 monitoring are now stored here instead of in cfg file.
June Release (26 June 2015)
- Updated Thor B-Scope2 support for new stage controller firmware
- Panning, scroll wheel zoom, and point-to-point alignment in alignment gui
- Automatic photostim monitor calibration
- Improved stimulus editor functionality
- Fix issue causing acquisition to randomly stop with a data corruption error
- Fix for Thor ECU1 component trigger routing
- Fix photostim shuttering functionality
- Fix photostim monitoring display behavior during focus
- Fix to multiple issues after switching between imaging systems
- Fix to AO generation when resonant angular range is different from x galvo angular range
- Fix issue when importing cell picker rois in linear scanning mode
- Fix to stimulus roi constraints
- Fix loading of channels in opentif
May Release (31 May 2015)
First release of ScanImage 2015! New features including:
- Multiple region of interest support
- Linear scanning
- Parallel scanning
- Photostim
- Improved stability
- Many more!