Description:
The 'Generate ScanImage Report' utility is a report generator function for ScanImage 2015.
Directory Location:
<ScanImage Application Directory>/+scanimage/+util/
Syntax:
scanimage.util.generateSIReport(attemptSILaunch, filename)
Input/Output Parameters:
- attemptSILaunch
'attemptSLaunch' is a boolean value that indicates whether (true) or not (false) ScanImage should be launched if not already running. - filename
'filename' is the fully qualified name of the zip file where the Report data is to be placed.
Details: The 'Generate ScanImage Report' utility launches ScanImage, if indicated and needed, and generates a set of files packaged together in a zip file, with the given filename.
Information included in the report:
- <filename>.cfg
ScanImage binary configuration file. - <filename>.user
ScanImage binary user file. - <filename>_NIMAX.zip
Compressed file containing extensive NI information generated using the NI's reporting API. - <filename>_temp.mat
A MATLAB file that can be used to browse through the report information in MATLAB. - Machine_Data_File.m
Machine data file configured for the version of ScanImage running at the time the report is produced. - TiffHeader.txt
Configuration and ScanImage settings data collected from the current running ScanImage instance at the time the report is generated. This is the information placed in a Tiff file when saving scanned images to a Tiff. - mSessionHistory.txt
MATLAB session history. - mFullSession.txt
MATLAB full session information.
- <filename>.cfg
- NIMAX Information:
- NI Installation Logs and Summary
- NI MAX Logs
- NI MAX Schema Log
- NI MAX Reports
- NI Services Status
- NI Configuration Settings
- VISA Configuration Settings