PHOTOSTIMULATION CONTROLS Panel
Sequence mode (left); on-demand mode (right)
Overview
The PHOTOSTIMULATION CONTROLS panel is used for configuring and controlling execution of 2D-scanned stimulation patterns.
Main Panel
Photostim Mode | Set photostim module to operate in either sequence or on-demand mode. See the photostimulation documentation for details on each operating mode. |
Trigger Source | Select the source of stimulation triggers. There are three options for the trigger source:
|
Sync Source | Select the source of stimulation synchronization triggers. There are two options for the trigger source:
|
Stim Immediately | Execute a stimulus immediately on start, rather than waiting for a trigger. The specific behavior depends on operating mode:
|
Stimulus Groups | Lists the stimulus groups that have been configured by their ID and name. A stimulus group consists of one or more stimulus functions that execute as a continuous waveform. |
Up | Moves the selected stimulus group up in the list. |
Down | Moves the selected stimulus group down in the list. |
Copy | Makes a duplicate copy of the selected stimulus group |
New | Creates a new empty stimulus group |
Edit | Opens the stimulus editor to edit the selected stimulus group |
Delete | Deletes the selected stimulus group |
Sequence Mode
Stimulus Group Sequence | Specifies the sequence of stimulus groups by ID. |
Number of Sequence | Specifies the number of times the complete sequence should be iterated through before the experiment is complete and the photostim module automatically aborts. |
On-Demand Mode
Allow multiple outputs | Indicates whether a stimulus should be allowed to be triggered multiple times after an on-demand request is made.
|
Enable Hotkeys | Enables hotkeys when the photostim module is started in on-demand mode. Hotkeys are:
|
External Simulus Selection: Trig Term | Specifies PFI terminal that triggers an external stimulus request |
External Simulus Selection: Terms | Specifies PFI terminals to read when external stimulus request is made |
External Simulus Selection: Stimuli | Specifies stimulus groups that correspond to each PFI terminal specified above |
Stimulation Controls
Monitor: Show | Enables a real-time overlay of scan mirror positions in channel image windows |
Monitor: Logging | Enables logging of stimulus outputs to disk |
Start/Abort | Starts or aborts photostim module |
Trigger | Sends a software trigger signal |
Sync | Sends a software sync signal |
Status | Indicates the status of the photostim module |
Attachments:
image2016-6-16 12:55:38.png (image/png)
status.png (image/png)
syncbutton.png (image/png)
trigbutton.png (image/png)
startabort.png (image/png)
monitor.png (image/png)
logging.png (image/png)
extselstims.png (image/png)
extselterms.png (image/png)
extseltrig.png (image/png)
ennablehotkeys.png (image/png)
allowmult.png (image/png)
numseq.png (image/png)
groupseq.png (image/png)
stimimmediately.png (image/png)
sync.png (image/png)
trig.png (image/png)
mode.png (image/png)
delete.png (image/png)
edit.png (image/png)
new.png (image/png)
copy.png (image/png)
down.png (image/png)
up.png (image/png)
groups.png (image/png)
Photostim_od.PNG (image/png)
Photostim_seq.PNG (image/png)
color.png (image/png)
alpha.png (image/png)
save.png (image/png)
load.png (image/png)
copychan.png (image/png)
resettransforms.png (image/png)
generatetransforms.png (image/png)
scaleoffset.png (image/png)
videocolor.png (image/png)
pausevideo.png (image/png)
sourcechan.png (image/png)
Show window.png (image/png)
Alignment.png (image/png)
image2014-6-3 20:1:1.png (image/png)
powercontrolsc02.png (image/png)
powercontrolsc01.png (image/png)
powercontrolsb01.png (image/png)
powercontrolsa06.png (image/png)
powercontrolsa05.png (image/png)
powercontrolsa04.png (image/png)
powercontrolsa03.png (image/png)
powercontrolsa02.png (image/png)
powercontrolsa01.png (image/png)
PowerControlsPulldown.png (image/png)
PowerControls.png (image/png)