The IntegrationRoiManager weighs pixel values according to a mask and sums the weighted values to form the integration value. This integration value is displayed without further analysis. However, it might be desired to perform additional computation on the integration values (e.g. to calculate dF/F). This can be done by defining a post processing function.
The IntegrationRoiManager has a property 'postProcessFcn'. This property defines a function handle points to a function, which, by default, passes the integrationValues through without any processing. By changing this function handle, a different functionality can be achieved.
hSI.hIntegrationRoiManager.postProcessFcn = @myPostProcessingFunction; % overwrite the default value of 'postProcessFcn'
To get started with your own postProcessingFcn, inspect the default post processing function
integrationValues = integrationPostProcessingFcn(rois,integrationDone,arrayIndices,integrationValueHistory,integrationTimestampHistory,integrationFrameNumberHistory)
% This function is used to post process integration values
% standard behavior: pass the integration values through without changing the calculated values
integrationValues = integrationValueHistory(arrayIndices);
end
This function can be changed to use the integration history for generating values:
integrationValues = integrationPostProcessingFcn(rois,integrationDone,arrayIndices,integrationValueHistory,integrationTimestampHistory,integrationFrameNumberHistory) historyLength = size(integrationValueHistory,1); numRois = size(integrationValueHistory,2); [is,js] = ind2sub(size(integrationValueHistory),arrayIndices); % get the line and row indices of the current integration values is = [is-2;is-1;is]; % % get row indices for last three values is(is<1) = historyLength - is(is<1); % integrationValueHistory is a rolling buffer. roll over rowindex over if i < 1 js = [js;js;js]; idx = sub2ind(is,js); % get 3xn index matrix vals = integrationValueHistory(idx); % get last 3 values for each integration roi integrationValues = mean(vals,1); % average last 3 values, return post processed value end
Note: only values that are flaged by 'integrationDone' actually were updated when the post processing function was called. To optimize for performance, only these values need to be post processed
integrationValues = integrationPostProcessingFcn(rois,integrationDone,arrayIndices,integrationValueHistory,integrationTimestampHistory,integrationFrameNumberHistory) historyLength = size(integrationValueHistory,1); numRois = size(integrationValueHistory,2); arrayIndices_ = arrayIndices(integrationDone); % get arrayIndices for values that changed [is,js] = ind2sub(size(integrationValueHistory),arrayIndices_); % get the line and row indices of the new values is = [is-2;is-1;is]; % % get row indices for last three values is(is<1) = historyLength - is(is<1); % integrationValueHistory is a rolling buffer. roll over rowindex over if i < 1 js = [js;js;js]; idx = sub2ind(is,js); % get 3xn index matrix vals = integrationValueHistory(idx); % get last 3 values for each integration roi integrationValues = nan(1,numRois); integrationValues(integrationDone) = mean(vals,1); % only update relevant values end
Application idea: overwrite the integrationValue of the last roi to show a peak every 30th frame
integrationValues = integrationPostProcessingFcn(rois,integrationDone,arrayIndices,integrationValueHistory,integrationTimestampHistory,integrationFrameNumberHistory)
integrationValues = integrationValueHistory(arrayIndices);
% overwrite value for last integration roi
frameNumber = integrationFrameNumber(arrayIndices(end));
tfmultiple30 = mod(frameNumber,30)==0;
if tfmultiple30
integrationValues(end) = Inf;
else
integrationValues(end) = 0;
end
end